Injection molding production is a combination of technology-intensive and labor-intensive production. It's an equipment-centric process that demands high stability from equipment and molds, requires precise setting of process parameters. Semi-automated production essentially adds value to products through a combination of manual labor and equipment. Changeover times are long, requiring mold replacements for different products, involving switching various interfaces such as water, oil, air, electrical systems, resulting in numerous steps and significant time consumption.
Traditional economic batch size (EBMS) theory considers mold changeover time unavoidable, hence concept of "economic batch size." However, lean manufacturing believes that any inventory is wasteful, arguing that producing one unit at a time is the lowest and most economical cost, and that EBMS doesn't need to be calculated. To achieve this, mold changeover time must be shortened, but in actual production, "zero changeover" is inherently impossible. If quick mold changeover technology can be combined with EBMS theory to shorten changeover time, then production batches will naturally decrease, thereby reducing storage costs. This will undoubtedly bring greater economic benefits to enterprises. With shortening "changeover" time as core, combining lean production theory and 6S management methods, an objective, scientific, and effective implementation process is proposed. Mold changeover process mainly consists of: mold changeover preparation, mold change, adjustment. Based on whether mold changeover operation requires machine downtime, mold changeover time can be further divided into internal mold changeover time, external mold changeover time, and adjustment time. External mold changeover time refers to time during which mold changeover operations can be performed without machine downtime. Common operations in this category include: receiving new work instructions, retrieving raw materials from material warehouse, retrieving new molds from mold warehouse, returning existing molds to mold warehouse, arranging lifting equipment and personnel required for next stage to designated location, and post-mold changeover cleanup. Internal mold changeover time refers to time during which machine downtime is required for mold changeover operations, including: removing workpieces from machine, dismantling original mold, cleaning workbench, installing new mold, etc. Adjustment time refers to time during which production is halted after mold changeover is completed to ensure product quality, precision, and troubleshooting. It includes: machine parameter debugging, mold position adjustment, and time consumed in parts trial production. After distinguishing between internal die changeover time, external die changeover time, and adjustment time, different measures can be taken to shorten die changeover time and achieve rapid die changeover. Division of die changeover time is shown in Figure 1-8, and typical die changeover steps are shown in Figure 1-9.
Quick Mold Changeover 
Quick Mold Changeover 
Japan's slogan is to challenge die changeover time to the second. Rapid die changeover (single minute exchange of die, SMED) means completing die changeover within a single minute (less than 10 minutes). Rapid die changeover (SMED) technology was proposed by Dr. Shigeo Shingo, an engineer at Toyota Motor Corporation in Japan, in 1969. This method can minimize die changeover time, production start-up time, adjustment time. Rapid die changeover utilizes two major technologies: methodological research and work measurement. Using "5W1H" and "ECRS four principles," each procedure in die changeover process is analyzed to identify problems and explore potential improvements. Aim is to improve overall equipment efficiency (OEE) by shortening die changeover operation time, increasing equipment utilization, enhancing manufacturing flexibility. This reduces labor intensity and improves work efficiency by improving equipment.
Each mold requires different parameters such as clamping force, ejector pin position, and operation sequence. During mold adjustment, process personnel rely on memory and experience to adjust initial part, which is time-consuming. To shorten adjustment time, DOE technology is used to optimize process parameters, reduce molding cycle time, and implement standardized management, creating a standard molding condition parameter table. When adjusting machine, personnel set parameters according to standard molding parameter table, reducing adjustment time by 10 minutes and improving mold change efficiency by 10%.
Above content summarizes three key elements of SMED (Surgical Equipment Changeover) operations: internal and external operations, rapid insertion and removal, centralized water and oil drainage.
Place molds on designated storage shelves (using rolling supports for easy movement, clearly labeling frequently used storage locations for easy retrieval). Attach three-color status tags to molds (red: need repair; green: maintenance completed; yellow: need maintenance). Position molds facing easily identifiable directions. Place frequently used molds closest to user, striving to streamline external mold changing operations. Information-based mold design allows mold information to be stored in mold via chips. When selecting a mold, operator scans it with a handheld terminal. Required mold can be located quickly and easily.
Method of mold mounting is the most significant factor affecting rapid mold changeover. Bolts and clamping plates are the most common methods for fixing molds. However, installing and removing these bolts requires complete removal, which is very time-consuming. Actions of installing and removing bolts during mold changeovers typically consume a large portion of changeover time. Therefore, the best solution to reduce internal operation time is to eliminate use of bolts for fixing.
Injection molds typically use locating rings for centering, aligning mold with center of injection machine nozzle. However, nozzle center is often difficult to see during mold stacking. To address these issues, when a crane lifts the mold vertically from above injection machine, a V-shaped locating seat and fixed side seat can be used, eliminating need for complete reliance on locating ring. Figure 1-10 shows a mold stacking system used by a French company using a V-shaped locating seat. When crane enters laterally, a sliding transport platform should be used, with a lateral stop on fixed mold plate, facilitating easy mold handling.
Quick Mold Changeover 
Rapid mold change requires rapid mold stacking and quick insertion/removal of sprue nozzles. For large molds, centralized oil and water channels facilitate rapid insertion and removal. There are many methods for rapid mold stacking; the most common are as follows:
1. Mechanical rotary clamping type. This is an earlier quick mold change system. Its characteristics include center clamping at the back of mold, suitable for small to medium-sized injection molding machines. Its mechanical structure is relatively complex, with clamping force concentrated at the center of rear of mold back plate. Advantages of this system are: mold is completely open on all sides, without any clamping elements, facilitating connection and arrangement of external pipelines. Disadvantages are: a unified clamping mechanism needs to be installed on mold back plate. Due to lack of clamping force around back plate, mold deformation and wear are significant during operation, clamping elements wear severely, and there is no status feedback signal from clamping elements to main unit. System is difficult to install and maintain, making it unsuitable for retrofitting existing equipment.
2. Hydraulic clamping platen type. This is the most common quick mold change system, which uses hydraulic clamps to hold mold. Characteristics of this system are: hydraulic system and control are relatively complex, and mold back plate clamps around perimeter. Advantages of this system are: easy installation and suitability for various sizes of hydraulic injection molding machines. Disadvantages of this system are: mold back plate specifications must be uniform; because there is no clamping force in core of back plate, larger molds experience greater deformation and wear during operation; clamping components suffer severe wear; there is no status feedback signal from clamping components to main unit; oil leakage and pollution occur; and it is unsuitable for fully electric injection molding machines; hydraulic clamping platen is located around mold, interfering with connection of external pipelines; hydraulic clamping platen protrudes from machine template and is easily damaged during mold changes; hydraulic system and actuators require regular maintenance.
3. Magnetic chuck type. This is a rapidly developing quick mold change system that has been widely accepted and adopted by industrialized countries in Europe and America in recent years. In recent years, most companies have shifted from traditional hydraulic mold change systems to magnetic systems. System's characteristics are: very simple structure and control; no mechanical clamping elements or movements; on contact surface between mold back plate and magnetic poles of chuck, whether in core or periphery, everything is clamped by permanent magnets. It is suitable for various types and sizes of injection molding machines. Basic principle of this technology is: using electrical control to change magnetic circuit distribution of permanent magnets, relying on permanent magnets to attract mold; clamping and releasing process takes only a few seconds; no electricity is required during operation; clamping force can reach 15 kgf/cm² on the entire contact surface, ensuring normal operation for molds of any weight on any tonnage injection molding machine.
Advantages of this system are: easy installation; suitable for various sizes of hydraulic and fully electric injection molding machines; clamping force comes from permanent magnetic materials; clamping status is fed back to host machine in real time, ensuring absolute clamping safety; due to uniform clamping force across the entire contact surface, mold deformation and wear are minimal during operation. System offers high precision and consistency in injection molded parts, extending mold life. With no actuators around mold, external piping connections are convenient. System has no mechanical movement and consumes electricity only momentarily, requiring no maintenance and boasting an extremely long lifespan.
System's disadvantage is that thickness of magnetic template (54mm + 54mm) has a certain impact on mold opening stroke of small injection molding machines. When using quick mold change system, standardization of mold design must be fully considered. Based on size of mold and injection molding machine, following four methods should be selected:
Manual center injection molding machine under 200t Hole locking system; small 47mm square/round magnetic pole electromagnetic chucks for injection molding machines under 400t; 80mm square magnetic pole electromagnetic chucks for injection molding machines over 400t; hydraulic clamps and pneumatic-hydraulic pumps for large injection molding machines, or modifications to self-propelled mold clamps, used in conjunction with quick-connect couplings, hydraulic circuit frequency dividers, mold changing carts, etc., to reduce internal operation time and achieve rapid mold changing.
Rapidly developing magnetic chuck mold changing system features advanced technology, high efficiency, safety, energy saving, and environmental protection, as detailed below.
1. Saves mold loading and unloading time and improves work efficiency. Only a safety key switch and a charge/demagnetize button are needed to securely and safely fix and disassemble mold within seconds, saving over 90% of loading and unloading time compared to traditional clamping methods.
2. Maximizes use of injection molding machine's mold space. Electro-permanent magnet quick mold change system saves more space by eliminating use of pressure plates and other pneumatic and hydraulic components, significantly increasing mold capacity of injection molding machine. It also makes peripheral equipment of mold easier to maintain and operate.
3. Protects mold and extends its lifespan. Traditional mold clamping methods result in point stress on mold, with stress points being a few points around mold. In contrast, electro-permanent magnet quick mold change system distributes force evenly across surface.
4. Safety. Electrically controlled permanent magnet template possesses strong magnetic force, eliminating need for electrical, oil, air circuits and accumulators found in traditional mechanical, hydraulic, and pneumatic clamping systems. This avoids safety hazards caused by power outages, oil or gas leaks, or fatigue damage to clamping bolts.
5. Energy-saving and environmentally friendly. Quick mold change system only requires electricity during extremely short charging/demagnetizing period. During normal use, it maintains a safe and strong adsorption force without requiring any energy, produces no environmental pollution such as oil stains or noise, making it both economical and environmentally friendly. Since no clamps are needed, it eliminates additional costs associated with screws, nuts, pressure plates, special tools, and wastewater treatment, and also eliminates need for special maintenance of electro-permanent magnet system.
Mold changes in injection molding machines are a troublesome and accident-prone process. Traditional mold fixing methods are not only time-consuming and labor-intensive but also pose significant safety hazards. Electro-permanent magnet quick mold change system is the latest generation of quick mold change systems for injection molding machines, widely used in European, American, and Japanese markets. Product is safe, reliable, flexible, and agile, allowing for rapid mold changes of various molds on a single injection molding machine, making it particularly suitable for multi-variety, small-batch, just-in-time mixed production. Furthermore, clamping force is evenly distributed across the entire contact surface between mold and disk, eliminating stress cavities on the back of mold, better ensuring mold closing accuracy, significantly reducing mold wear, increasing mold life, and lowering production costs.