Cooling System Design

Time:2026-11-20 08:48:03 / Popularity: / Source:

I. Requirements for Cooling System Design

Simple layout, convenient pipe connection; Symmetry; Ensure required number of loops; Consider mold plate size and available space on injection molding machine; Size and number of screws used on mold plate; Components and distances of ejection system; Position and size of guide pillars and bushings; Optimal cooling effect; Cost.

II. Key Points of Injection Mold Cooling System Design

1. General Design Principles of Cooling Systems
Generally, following principles should be considered when setting up a cooling system:
Diameter, spacing, and distance to cavity surface of cooling pipes all have a significant impact on mold temperature control. Maximum values of these ratios are as follows; for example, when diameter of cooling pipe is 1, maximum spacing between pipes is 5, and maximum distance between pipe and cavity surface is 3. In addition, for thicker parts of molded material, spacing of cooling water pipes must be reduced and they need to be closer to cavity surface. To maintain a uniform mold temperature distribution, cooling water should first enter from hotter areas of mold, then circulate to cooler areas before flowing out. Typically, molding material near runner and gate has a higher temperature, so cold water flows through there. Cooler outer parts circulate warm water for heat exchange. Piping connection for this circulation system involves through-holes machined inside mold and connecting holes outside mold. When molding materials with high shrinkage, such as PE, cooling pipes should not be along shrinkage direction due to large molding shrinkage. Cooling pipes should be installed along contour of cavity as much as possible to maintain a uniform mold temperature distribution. There should be no short circuits or stagnation in cooling water flow, otherwise cooling effect will be affected. Furthermore, through-holes should be used in cooling pipes whenever possible for easy cleaning later. Diameter, number, and distribution of water holes should be reasonably selected during design. Cooling should be strengthened for thick-walled areas. To ensure uniform mold cooling, temperature difference between cold water inlet and outlet should be small. Generally, temperature difference should be less than 5℃. For precision products, temperature difference should be less than 3℃. Furthermore, when cooling circuit length is 1.2~1.5m or longer, number of runners and flow rate need to be increased. Turbulent flow is best for optimal cooling.
2. Cooling System Design Specifications
For small molds, distance between cooling channel and inserts, ejector pins, other boundaries should be greater than or equal to 3mm. Since longer drilled holes have greater skewness, for large molds, distance between cooling channel and inserts, ejector pins, and other boundaries should be greater than or equal to 5mm. Sliders and ejectors should also have water channels if possible, as different mold temperatures can affect product appearance. All slides wider than 60mm require water channels. Ejectors larger than 30mm x 30mm require adequate cooling. Hot runner plates, A-plates, and B-plates also require water channels to reduce mold temperature. Ideally, the area near hot runner of mold core and mold base should have independent water channels. Distance from water channel wall to mold platen should be 10-15mm. Use smaller value for small molds and larger value for large molds. When designing water channel, consider that gateposts will not interfere with water channel connection on the outside of mold, and that components on slider will not touch gateposts when slider moves. For molds made by injection molding machines of 150t or more, diameter of direct cooling water passage should be 10mm or more. For molds made by injection molding machines below 150t, diameter of cooling water passage should be 8mm or more. Diameter of water channel should be 66mm or more. Maximum diameter of cooling water channel passage for large molds can be 20mm.
3. Design of Water Collection Blocks for Large Molds
Large molds have many water channel circuits. When designing mold, water collection blocks need to be designed to unify water channel circuits. Water collection blocks should be placed on the top side as close as possible to non-operating side, followed by non-operating side. There should be a maximum of 8 water channels on one side of moving and fixed molds, with all water channels entering and exiting through water collection blocks. Water collection blocks should be numbered 1, 2, 3, 4... Water collection block needs a label explaining water circuit details. 3D design should include machine's header or panel and mold mounting location, then consider whether water connectors, hoses, and water collection blocks will affect mold installation or cause interference. Water circuit connection method and hose connectors need to be shown in 3D design, and water circuit connection method needs to be confirmed during design phase.

III. Cooling System Design Considerations

Distance between two adjacent water supply groups must not be less than 30mm, otherwise it will cause interference with water nozzle connectors. Water inlet and outlet positions must be considered to ensure they do not interfere with mold mounting platen, preventing water supply installation on injection molding machine. Mold assembly drawing must indicate top side, which is direction of mold lifting. Water supply connectors should ideally not be designed on the top side of mold to avoid affecting robot's ejection. Priority order for water supply connector design locations is: reverse operation side - operation side - ground side - top side. Leaks at top side connectors can lead to mold core rusting and may also affect robot movement during automated production. Water supply on ground side is difficult to install, and products can easily get caught on water pipes when they fall automatically. From a safety and production perspective, water supply outlet should ideally be on non-operational side. Export molds are required to have water pipes connected to non-operational side. For water supply within export mold, copper plugging is not permitted; plug screws must be used instead. Water supply nameplate design must include markings for water inlet and outlet. Common markings are 1IN, 1OUT, etc. For molds exported to Germany, water supply inlet and outlet are marked with E1 (in), A1 (out), E2, A2, etc. For molds exported to France, water supply inlet and outlet are marked with E1 (in), S1 (out), E2, S2, etc. When mold has multiple cooling circuits, cooling water should first enter area closest to main flow channel. Water channel design principle is to diffuse outwards from center, inlet and outlet positions of each cavity should be same to ensure consistent product molding conditions. Cooling water channels must be installed at the front of flow channel. Enhance gate cooling: Temperature near gate is highest during plastic filling, so enhanced cooling is essential. When inserts have water-cooling rings underneath, mounting brackets cannot be used; inserts must be secured with screws. Precision molds and medical product molds are typically made of stainless steel to prevent rusting of cooling channels.

IV. Ways to Improve Mold Temperature Regulation

Maximize diameter of cooling water holes and number of cooling channels on mold to increase heat transfer area, shorten cooling time, and improve production efficiency. Steel is usually chosen as mold material, but in areas where heat dissipation is difficult, beryllium copper, aluminum alloy, or other mold materials with high thermal conductivity can be used as inserts, provided mold rigidity and strength are guaranteed. Room temperature water is generally used as cooling medium, ideally with a temperature difference of less than 5℃ between inlet and outlet. Flow rate of cooling water should be as high as possible, and turbulent flow is preferred. Cooling circuit distribution should be uniform, meaning distance between cooling circuit and cavity, and spacing between water channels, should ensure uniform temperature on cavity surface. Cooling water channels should avoid being near areas where weld lines may occur. Cross-section of same circuit and cooling channel must be equal. Cooling circuit inlet and outlet must form a single loop to avoid stagnant water. In actual injection molding production, cooling water should be shut off before last 30 mold passes to ensure mold has sufficient heat to prevent condensation on cavity walls.
Higher thermal conductivity results in better heat transfer efficiency, making heat control and removal easier. In other words, higher thermal conductivity leads to less surface temperature variation in mold's forming space, while lower conductivity results in greater surface temperature variations. Generally, when molten material fills forming space, temperature near gate is high, and temperature decreases further away from gate. If molded part is divided into several sections, heat of each section is proportional to its volume. To improve molding efficiency and obtain products with less strain, mold structure must be able to adapt to shape of molding space or thickness of plastic part, enabling uniform and efficient cooling. Number, size, and configuration of cooling pipes are extremely important when machining mold. Temperature distribution on the surface of molding space varies depending on size, configuration, and water temperature of water pipes. Excessive spacing between water channels can lead to uneven mold surface temperatures, reducing cooling effectiveness. Normally, distribution of cooling pipes should ensure that distance from cooling water pipe wall to plastic part is approximately twice water channel diameter. The thicker plastic part, the more heat needs to be removed; relationship between plastic part thickness and cooling water pipes is shown in Figure 10-2.
Injection Mold Cooling System Design 
Figure 10-2 Relationship between adhesive thickness and cooling water pipe

V. Preventing Part Deformation through Mold Temperature Regulation

Large, flat plastic parts are prone to deformation due to stress, resulting in surface warping. During injection molding, deformation needs to be regulated by improving temperature difference in water circulation circuit. In this case, water circulation circuits of moving and fixed molds should be arranged vertically and horizontally at 90° intervals to facilitate localized temperature regulation. Figure 10-3 shows an example of improving deformation of a printer bracket plastic part through vertical water distribution. Figure (a) is a schematic diagram of water distribution in fixed mold, where water distribution loop is perpendicular to long side of mold frame; Figure (b) is a schematic diagram of water distribution in moving mold, where water distribution loop is parallel to long side of mold frame. Spacing between water channels should ideally be 38-55mm, depending on mold size. Minimum distance should not be less than 30mm, otherwise, interference may occur between adjacent water distribution joints.
Injection Mold Cooling System Design 
Figure 10-3 Vertical distribution of water channels in moving and fixed molds improves plastic part deformation.

Go To Top