Correct injection workshop changing process, please check!

Time:2023-10-21 15:45:35 / Popularity: / Source:

1. Personnel must be familiar with and strictly abide by security codes.
2. Before hanging mold, check motion status of crane and whether function of each button is sound normally, and whether ring is installed firmly
Is there a disclosure of steel rope? Is there an overweight? If you find a problem, you should stop working immediately.
injection workshop 
3. When installing hook, it is strictly forbidden to operate crane while putting hook on, so as to prevent fingers from being caught between hook and ring, being injured.
4. When lifting mold, you should concentrate your thoughts and be careful to see direction of button to prevent accidents when you press wrong button.
5. Prepare all tools and throat mouths before mold (wrapped throat and leak -proof tape) to reduce time after mold is suspended. Mold should be lifted slowly (not suddenly and quickly) at the beginning. Height of lifting mold should be below 80CM. Only when mold is moved to vicinity of fuselage can it be raised to prevent mold from falling halfway and hurting people.
6. During lifting mold, person in aisle should be notified to let it open, and use left hand to support side of mold to prevent mold from turning or bumping. It is strictly forbidden to hang hanging mold from place/above/operating keyboard or above screen to prevent mold from falling down or damaging machine.
7. It is strictly forbidden to stand under hanging items (molds). When hanging mold, operator should keep a distance (horizontal direction) with mold of more than 1 meter. When installing throat mouth under mold, any part of body is not allowed to be located in the area where mold is falling, so as to prevent mold from falling down.
8. It is strictly forbidden for mold to stay in the air for a long time (more than 10 minutes) or lifter to leave site for a long time.
9. When crane breaks down or abnormal phenomena occur during operation of crane (such as: abnormal noise, motor does not operate, or lifted object automatically slides down, etc.), lifted object should be put down immediately, stop using crane, put up a "prohibited use" notice board, and notify IE department to send personnel to overhaul.
10. Before installing mold, reduce speed of opening/synthesis to about 25%, and adjust operation button to manually (zero) to be in a "low -pressure manual" state.
11. Turn off power supply of oil pump motor when loading mold. When adjusting position of mold in machine, try not to move mold by pulling hanging chain. If necessary, use method of "lifting" to pull mold forward slowly. Do not use too much force to prevent suspension chain from being broken and accidents.
12. When nozzle is right, it is strictly forbidden to place your hand between mold and nozzle. When cannon is advancing, it is forbidden to clean up melting glue, foreign body and adjustment/watching position of mouth hole near nozzle hole to prevent being clamped between mouth injection and mold.
13. When coding is coded, it must be firm and reliable. After mold is installed, hook/ring can be removed.
14. After mold is installed, hook must be removed to open mold inspection or adjust mold/motion and pointer movement. It is strictly forbidden to open mold without removing hook to prevent safety accidents.
15. During upper/lower mold operation or when nozzle is aligned, safety gloves must be worn to prevent metal from scratching hands or high-temperature nozzle from scalding hands.
16. It is strictly forbidden to use melting glue or heating ring of hot ring with your hands. When you need to take heating head, you must wear gloves to prevent scalding your hands.
17. Cleaning cannons should be reduced to less than 50%. Do not use high -speed and high pressure to use high -speed high -pressure glue, and put rash protective baffle to put it into use to prevent high temperature melting glue from splashing injury. During cleaning of machine, it should be prevented by others from approaching nozzle or standing near nozzle.
18. Do not put your hands and faces nearly high -temperature mouth injection or cannon to prevent burns. It is not allowed to stand on heating tube cover to prevent burns, leakage and injury.
19. When feeding bucket is removed, it is not allowed to make melting or adhesive action. It is strictly forbidden to put your hand into bucket mouth when screw rotation is strictly prohibited to prevent fingers from being strangled by screw.
20. When two people need to cooperate with upper and falling molds, before operating machine, whether the other's molds are installed and disassembled, and check whether the other party stops cleaning, maintenance, installation of molds, etc.? The other party must also say hello to operator, and do not start power supply.
21. When installing, disassembling, inspecting, cleaning up molds and adhesive mold products, operation status should be switched to "cut" or "low pressure manual" position for operation, and power supply of oil pump motor (red emergency stop button) should be turned off at any time, and a warning sign of "prohibit starting oil pump motor" should be hung.
22. When checking heating (heating ring) or exposed wires, power supply of heater line must be turned off to prevent electric shock.
injection workshop 
23. When someone cleans or repair mold, it is forbidden for anyone to start power supply or operating panel/adjustment parameters to prevent accidents.
24. Before removing screw, shoot all rubber in ingredients (cannon). When disassembling screw, you should first turn off heating power and operating power supply. People must not stand in direction of screw demolition.
25. Mold is placed smoothly, and stacking should not be too much or too high, so as not to hurt mold. Speed of pulling mold should not be too fast to prevent collision from hurting others.

Go To Top